Minimum Distance Of Window To Floor In Bedroom

The base of the well can be no more than 44 inches above the bedroom floor.
Minimum distance of window to floor in bedroom. Bedroom windows are also subject to some safety considerations. An exception from this requirement also remains in the 2018 irc for windows that do not open more than 4 inches or that are. Allow the rescue window opening to be fully opened. The trickiest part is the window egress.
Exceptions can be made for windows that do not open more than 4 inches or that have window guards or opening control devices in compliance with astm f2090 17. Except on the ground floor where it must be 5 s f. According to the 2018 irc all windows that are more than 6 feet above the grade outside the window must have a bottom opening a minimum of 24 inches above the room s interior floor. However if the window extends to within 18 inches of the floor it must either be safety glazed or have a bar or other physical barrier to prevent someone from falling into the glazing.
To qualify a basement window as an egress you may also have to install window wells to enlarge windows and allow access. If the sill is below ground the window itself will need larger dimensions 9 square feet. Of floor area with a minimum dimension of 36 in. According to code check complete.
The 2018 irc continues to require the bottom of openings created by operable windows to be a minimum height of 24 inches above the adjacent interior floor when they are more than 6 feet above the grade outside the window. Window wells greater than 44 inches in depth requires a permanently fixed ladder or steps to provide access. An illustrated guide to the building mechanical and electrical codes by redwood kardon et al conditions requiring a window to have tempered glass include a window lower than 18 inches from the ground larger than 9 square feet in area with a top higher than 3. The minimum net clear opening is 5 7 s f.
Besides the height width and overall square footage requirements that the bedroom window must meet there are certain requirements for the window well surrounding the window. Window wells serving an egress window shall not be less than 9 square feet in area with a horizontal length width of no less than 36 inches. In width and in length. Glazing between the floor and 24 inches.
Where to install windows with tempered glass is not just dictated by the height of the window. There is no minimum distance that a window must be from the floor even for second story windows. The minimum opening height is 24 and the minimum width is 20 inches. Maximum 44 inches to window sill measured from finished floor.